Tel: +86-13167190983 Correo electrónico: michael@shanghaiyunigroup.com

Acerca de Contacto |

YUNI SINGLE CORE 34.5KV 4/0 CABLE COPPER 100% TRXPLE URD Cable - Grupo Yuni de Shanghái

ABC Cable/

YUNI SINGLE CORE 34.5KV 4/0 CABLE COPPER 100% TRXPLE URD Cable

Conductor Material: Cobre

Insulation Material: Caucho

Number of Conductors: SINGLE CORE

Place of Origin: Shanghái, China

Brand Name: YUNI

Chaqueta: Caucho

Product name: SINGLE CORE

Material: Silicone Rubber

Type: Self-adhesive

Director: Tinned Copper Conductor

Size: Customized Size

Certification: ISO9001/ISO14001 /OHSAS18001/CCC

MOQ: 100 Meters

Quantity (meters): 1 - 1500 > 1500

Lead time (days): 15 To be negotiated

  • Detalles del producto

YUNI SINGLE CORE 34.5KV 4/0 CABLE COPPER 100% TRXPLE URD Cable

Copper Conductor 15KV URD – Full Neutral 133%

Application:

Copper Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use. Conductors: Copper Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn copper conductor per ASTM. Conductor Shield: Copper Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation. Aislamiento: Copper Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request. Metallic Shield: Copper Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield. Chaqueta: Copper Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.

Standards:

ASTM B-3, B-8,

B230, B-231,

B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous,

130°C emergency and 250°C short-circuit operation

Part Number Director Instulation Thickness (mils) Concentric Neutral Conductor Diameter (inches) Insulation Shield Diameter (inches) Jacket Diameter (inches)
CU-15KVURD-133%-FN-2SOL 2 SOL 220 16-#14 0.258 0.81 1.05
CU-15KVURD-133%-FN-2STR 2 STR 220 16-#14 0.284 0.84 1.08
CU-15KVURD-133%-FN-1SOL 1 SOL 220 13-#12 0.289 0.84 1.11
CU-15KVURD-133%-FN-1STR 1 STR 220 13-#12 0.324 0.88 1.15
CU-15KVURD-133%-FN-1/0SOL 1/0 SOL 220 16-#12 0.325 0.88 1.15
CU-15KVURD-133%-FN-1/0STR 1/0 STR 220 16-#12 0.364 0.92 1.19
CU-15KVURD-133%-FN-2/0STR 2/0 STR 220 13-#10 0.408 0.96 1.28
CU-15KVURD-133%-FN-3/0STR 3/0 STR 220 16-#10 0.458 1.01 1.33
CU-15KVURD-133%-FN-4/0STR 4/0 STR 220 16-#9 0.515 1.07 1.41

 

Contesta